| Thermogenic mechanisms during the development of endothermy in juvenile birds | ||
|---|---|---|
| Prev | Chapter 4. Material and methods | Next |
Shivering EMGs were recorded from the pectoral (II–V), gastrocnemius (II–IV) and iliofibularis muscles (III). Measurements were performed using bipolar subcutaneous electrodes made of Teflon-coated multistranded steel wire. The EMG signals picked up with the electrodes were fed into differential amplifiers, displayed on an oscilloscope, converted either to mean rectified values (Umrv) (II) or to rectified mean square values (Urms) (III, IV, V) with analog integrators, and were recorded either with a pen recorder (II) or with a Hewlett-Packard 34970A Data Acquisition/Switch unit connected to a PC (III, IV, V). Samples of the unintegrated 1000-fold amplified raw EMGs were stored on C-cassette tapes using a stereo cassette deck (II, IV). Frequency spectra for tape-recorded EMG samples were calculated using the Fast Fourier Transform with a DATA 6000 signal analyser (Data Precision Inc.). In 21-day-old Japanese quails, intramuscular EMGs were recorded 5 mm deep from the thickest part of the breast muscle 5 mm laterally from the keel of the sternum with bipolar electrodes made of Teflon-coated multistranded steel wire (Medwire®, part 316SS7/44T, Mt. Vernon, USA).